PRTs for laboratory freezers, autoclaves, and furnaces

  • 5606: -200 °C to 160 °C
  • Calibration accuracy of ± 0.05 °C
  • Transition junction and lead wires can withstand full PRT temperature range
  • Unique probe seal of 5606 prevents ingress of moisture
  • Calibration not included; NVLAP-accredited calibration optional

The 5606 Full Immersion PRTs are designed to perform in extreme environments where both the transition junction and the lead wires are required to withstand temperatures covering the entire operating range of the probe. (“Immersion” in this case simply means exposure to temperatures other than ambient and does not necessarily refer to the medium to which the PRT and its components are subjected.)

Applications where “full immersion” of probe, transition junction, and lead wire is required can include calibration or validation of sensors used in laboratory or bio freezers, walk-in refrigerators, autoclaves, ovens, stability test chambers, furnaces or incubators. Other applications might include IQ/ OQ/PQ qualification procedures, temperature mapping, or data logging in temperature controlled spaces or environmental chambers.


General Specifications
Temperature range
 –200 °C to 160 °C
Nominal resistance at 0.01 °C
100 Ω ± 0.1 Ω
Temperature coefficient
0.00385 Ω/Ω/°C
Accuracy[1]
 ± 0.04 °C at 0.01 °C
 ± 0.06 °C at 160 °C
Short-term repeatability[2]
 ± 0.03 °C at 0.01 °C
 ± 0.04 °C at 160 °C
Drift[3]
 ± 0.03 °C at 0.01 °C
 ± 0.04 °C at 160 °C
Hysteresis
± 0.015 °C
Sheath length
 50 mm ± 5 mm
 (2 in ± 0.2 in)
Sheath diameter
3.1 mm ± 0.1 mm (1/8 in ± 0.004 in)
Sheath material
 316 SST
Transition junction temperature range[4]
 –200 °C to 160 °C
Sensor length
30 mm ± 3mm (1.2 in ±0.1 in)
Sensor location
3 mm ± 1 mm from tip (1.2 in ± 0.04 in)
Minimum insulation resistance
 20 MΩ at 23 °C
Minimum immersion length
Full immersion
Maximum immersion depth in liquid medium
Full immersion
Response time[5]
12 seconds typical
Self heating (in 0 °C bath)
 ± 0.003 °C
Lead-wire cable type
 Enameled copper wire
Lead-wire length
2.4 meters (8 ft)
Lead-wire temperature range
 160 °C
Calibration
Calibration not included. NVLAP accredited calibration available. See ordering information.

[1] Includes calibration and 100 hr drift (k = 2).
[2] Three thermal cycles from min to max temp, includes hysteresis, 95 % confidence (k = 2).
[3] After 100 hours at max temp, 95 % confidence (k = 2).
[4] Temperatures outside this range will cause irreparable damage.
[5] Per ASTM E 644.

Calibration uncertainty
 
5606
Temperature 1924 Calibration Uncertainty Tolerance w/out Calibration
-197 °C 0.03 °C 0.4 °C
-38 °C 0.03 °C 0.2 °C
0 °C 0.03 °C 0.1 °C
100 °C 0.045 °C 0.3 °C
157 °C 0.05 °C 0.4 °C
 
 
 
Lab code 200348-0
Each PRT includes a certificate with a measured R0 value.
An uncalibrated 5606 meets ASTM E 1137 Grade A Classification of Tolerances. Use the coefficients below to achieve the tolerances listed in the “No Calibration” column or calculate the Grade A tolerance using the following formula: Grade A = ± [0.13 + 0.0017|t|]°C where: |t| = value of temperature (°C) without regard to sign. See ASTM E 1137.
R0: Enter the R0 value provided
A: 3.9083 x 10–3
B: –5.775 x 10–7
C: –4.183 x 10–12


상품결제정보

고액결제의 경우 안전을 위해 카드사에서 확인전화를 드릴 수도 있습니다. 확인과정에서 도난 카드의 사용이나 타인 명의의 주문등 정상적인 주문이 아니라고 판단될 경우 임의로 주문을 보류 또는 취소할 수 있습니다.  

무통장 입금은 상품 구매 대금은 PC뱅킹, 인터넷뱅킹, 텔레뱅킹 혹은 가까운 은행에서 직접 입금하시면 됩니다.  
주문시 입력한 입금자명과 실제입금자의 성명이 반드시 일치하여야 하며, 7일 이내로 입금을 하셔야 하며 입금되지 않은 주문은 자동취소 됩니다.

배송정보

  • 배송 방법 : 택배
  • 배송 지역 : 전국지역
  • 배송 비용 : 3,500원
  • 배송 기간 : 3일 ~ 7일
  • 배송 안내 : - 산간벽지나 도서지방은 별도의 추가금액을 지불하셔야 하는 경우가 있습니다.
    고객님께서 주문하신 상품은 입금 확인후 배송해 드립니다. 다만, 상품종류에 따라서 상품의 배송이 다소 지연될 수 있습니다.

교환 및 반품정보

교환 및 반품 주소
- 경기도 의왕시 오봉산단3로 25, 더리브비즈원 제1동 1520호 티엔피솔루션

교환 및 반품이 가능한 경우

- 상품을 공급 받으신 날로부터 7일이내 단, 가전제품의
 경우 포장을 개봉하였거나 포장이 훼손되어 상품가치가 상실된 경우에는 교환/반품이 불가능합니다.
- 공급받으신 상품 및 용역의 내용이 표시.광고 내용과
 다르거나 다르게 이행된 경우에는 공급받은 날로부터 3월이내, 그사실을 알게 된 날로부터 30일이내

교환 및 반품이 불가능한 경우
- 고객님의 책임 있는 사유로 상품등이 멸실 또는 훼손된 경우. 단, 상품의 내용을 확인하기 위하여
 포장 등을 훼손한 경우는 제외
- 포장을 개봉하였거나 포장이 훼손되어 상품가치가 상실된 경우
 (예 : 가전제품, 식품, 음반 등, 단 액정화면이 부착된 노트북, LCD모니터, 디지털 카메라 등의 불량화소에
 따른 반품/교환은 제조사 기준에 따릅니다.)
- 고객님의 사용 또는 일부 소비에 의하여 상품의 가치가 현저히 감소한 경우 단, 화장품등의 경우 시용제품을
 제공한 경우에 한 합니다.
- 시간의 경과에 의하여 재판매가 곤란할 정도로 상품등의 가치가 현저히 감소한 경우
- 복제가 가능한 상품등의 포장을 훼손한 경우
 (자세한 내용은 고객만족센터 1:1 E-MAIL상담을 이용해 주시기 바랍니다.)

※ 고객님의 마음이 바뀌어 교환, 반품을 하실 경우 상품반송 비용은 고객님께서 부담하셔야 합니다.
 (색상 교환, 사이즈 교환 등 포함)

서비스문의

상품사용후기

상품의 사용후기를 적어주세요.

게시물이 없습니다

상품후기쓰기 모두 보기

상품 Q&A

상품에 대해 궁금한 점을 해결해 드립니다.

게시물이 없습니다

상품문의하기 모두 보기